Remove-InitiatorId
Removes an initiator identifier (ID).
Syntax
ByAddress (Default)
Remove-InitiatorId
[-InitiatorAddress] <String[]>
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[-WhatIf]
[-Confirm]
[<CommonParameters>]
ByUniqueId
Remove-InitiatorId
-UniqueId <String[]>
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[-WhatIf]
[-Confirm]
[<CommonParameters>]
InputObject (cdxml)
Remove-InitiatorId
-InputObject <CimInstance[]>
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[-WhatIf]
[-Confirm]
[<CommonParameters>]
Description
The Remove-InitiatorId cmdlet removes an initiator identifier (ID).
Examples
Example 1: Remove an iSCSI initiator ID
PS C:\>Remove-InitiatorID -InitiatorAddress $SomeiSCSIIQN
This example removes the iSCSI IQN previously stored in the variable $SomeIscsiIQN from the list of Initiator IDs.
Parameters
-AsJob
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
Parameter properties
Type: | SwitchParameter |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-CimSession
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.
Parameter properties
Type: | CimSession[] |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Aliases: | Session |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-Confirm
Prompts you for confirmation before running the cmdlet.
Parameter properties
Type: | SwitchParameter |
Default value: | False |
Supports wildcards: | False |
DontShow: | False |
Aliases: | cf |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-InitiatorAddress
Specifies the address of the InitiatorID object you want to remove.
Parameter properties
Type: | String[] |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
ByAddress
Position: | 0 |
Mandatory: | True |
Value from pipeline: | False |
Value from pipeline by property name: | True |
Value from remaining arguments: | False |
-InputObject
Specifies the input object that is used in a pipeline command.
Parameter properties
Type: | CimInstance[] |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
InputObject (cdxml)
Position: | Named |
Mandatory: | True |
Value from pipeline: | True |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-PassThru
Sends items from the interactive window down the pipeline as input to other cmdlets. By default, this cmdlet does not generate any output.
To send items from the interactive window down the pipeline, click to select the items and then click OK. Shift-click and Ctrl-click are supported.
Parameter properties
Type: | SwitchParameter |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-ThrottleLimit
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0
is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Parameter properties
Type: | Int32 |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-UniqueId
Specifies the UniqueID(s) of the InitiatorID(s) you want to remove. Separate multiple UniqueIDs with commas, and enclose brackets in quotation marks.
Parameter properties
Type: | String[] |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Aliases: | Id |
Parameter sets
ByUniqueId
Position: | Named |
Mandatory: | True |
Value from pipeline: | False |
Value from pipeline by property name: | True |
Value from remaining arguments: | False |
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Parameter properties
Type: | SwitchParameter |
Default value: | False |
Supports wildcards: | False |
DontShow: | False |
Aliases: | wi |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable, -ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Inputs
CimInstance
You can pipe an InitiatorID object to the InputObject parameter.
Outputs
CimInstance
This cmdlet returns an object that represents an initiator ID.
Notes
- When used in Failover Cluster, cmdlets from the Storage module operate on cluster level (all servers in the cluster).