This is to test the z-axis reporting behavior of a Windows Precision Touchpad device.
Test name
- Test.ZHeight
Core requirements tested
- Device.Input.Digitizer.PrecisionTouchpad.ContactTipSwitchHeight
Test purpose
- Verifies that the device does not report contacts that exceed the allowable detection threshold in the z-axis.
Tools required
PT3 w/Precision Touchpad Modifications
PTLogo.exe
1mm thick non-conductive material (such as a business card)
Validation steps
Place 1mm thick material on top of touchpad.
Lower 1 PT3 contact until it just touches the non-conductive material.
Remove the material, leaving PT3 contact 1mm above the touchpad.
Launch Test.ZHeight.json.
Leave contact in place above touchpad for 1 minute.
Verify that no contact is reported – and if that is the case, then manually Pass the iteration. Otherwise manually Fail the iteration.
Common error messages
- None.
Passing criteria
- 1/1 (100%) iterations must pass in order to complete with passing status.