The following oplock break conditions apply when a stream is being written and the write is not a paging I/O.
Conditions for a Level 2 request type:
Always break to None.
No acknowledgment is required; the operation proceeds immediately.
Conditions for all other request types:
Break on IRP_MJ_WRITE when the write operation occurs on a FILE_OBJECT with an oplock key that differs from the key of the FILE_OBJECT that owns the oplock. If the oplock is broken, break to None.
Acknowledgment requirements vary as follows:
Read request: No acknowledgment is required; the operation proceeds immediately.
Read-Handle request: Although acknowledgment of the break is required, the operation continues immediately (for example, without waiting for the acknowledgment).
Level 1, Batch, Filter, Read-Write, and Read-Write-Handle requests: An acknowledgment must be received before the operation continues.